Vennligst vent...
Produktet ble lagt i handlekurven. Se handlekurven her

APC APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V

Forsiden UPS & Power Accessories APC APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V
Du må logge inn for å handle/se priser.
APC APC Smart-UPS X 3000VA Rack/ Tower LCD 100-127V (SMX3000RMLV2U)
APC APC Smart-UPS X 3000VA Rack/ Tower LCD 100-127V (SMX3000RMLV2U)
APC APC Smart-UPS X 3000VA Rack/ Tower LCD 100-127V (SMX3000RMLV2U)
APC APC Smart-UPS X 3000VA Rack/ Tower LCD 100-127V (SMX3000RMLV2U)

APC APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V

Varenr.:
SMX3000RMLV2U
EAN:
0731304268550
  • Kapasitet 3kVA
  • Produkt Ekstern UPS
Beskrivelse

APC Smart-UPS X 3000VA Rack/Tower LCD 100-127V


APC Smart-UPS, 2700 Watts / 3000 VA, Input 120V / Output 120V , Interface Port SmartSlot , Extended runtime model , Rack Height 2 U

Includes

CD with software, Documentation CD, Installation guide, Rack Mounting brackets, Rack mounting hardware, Rack Mounting support rails, Removable support feet, Smart UPS signalling RS-232 cable, USB cable

Output

  • Output Power Capacity 2700 Watts / 3000 VA
  • Max Configurable Power 2700 Watts / 3000 VA
  • Nominal Output Voltage 120V
  • Efficiency at Full Load 98%
  • Output Voltage Distortion Less than 5% at full load
  • Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal
  • Waveform Type Sine wave
  • Output Connections (3) NEMA 5-15R
  • (3) NEMA 5-20R
  • (1) NEMA L5-30R

Input

  • Nominal Input Voltage 120V
  • Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
  • Input Connections NEMA L5-30P
  • Cord Length 2.44 meters
  • Transfer Time 2-4 ms

Batteries & Runtime

  • Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Typical recharge time 3 hour(s)
  • Replacement Battery APCRBC117
  • RBC™ Quantity 1

Communications & Management

  • Interface Port(s) SmartSlot
  • Available SmartSlot™ Interface Quantity 1
  • Control panel LED status display with On Line : On Battery : Replace Battery and Overload indicators,Multi-function LCD status and control console
  • Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays
  • Emergency Power Off (EPO) Yes

Surge Protection and Filtering

  • Surge energy rating 540 Joules
  • Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
  • Data Line Protection --

Physical

  • Maximum Height 85.00 mm
  • Maximum Width 432.00 mm
  • Maximum Depth 667.00 mm
  • Rack Height 2U
  • Net Weight 38.45 KG
  • Shipping Weight 45.36 KG
  • Shipping Height 243.00 mm
  • Shipping Width 596.00 mm
  • Shipping Depth 869.00 mm
  • Color Black
  • Units per Pallet 8.00
  • # of Layers per Pallet 4
  • # of Units per Layer per Pallet 2
  • Pallet Weight 388.69 KG

Environmental

  • Operating Environment 0 - 40 °C
  • Operating Relative Humidity 0 - 95%
  • Operating Elevation 0-3000 meters
  • Storage Temperature -15 - 45 °C
  • Storage Relative Humidity 0 - 95%
  • Storage Elevation 0-15000 meters
  • Audible noise at 1 meter from surface of unit 55.00 dBA
  • Online Thermal Dissipation 276.00 BTU/hr

Conformance

  • Regulatory Approvals BSMI,CSA,EN 50091-2,EN 55022 Class A,FCC Part 15 Class A,NOM,TUV,UL 1778,VCCI Class A
  • Standard Warranty 3 years repair or replace (excluding battery) and 2 year for battery,optional on-site warranties available,optional extended warranties available

Features

Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.

Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.

UPS recognizes when external battery packs are attached and automatically adjusts runtime.

Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Provides actual kilowatt hours of usage for energy conscious users.

Configure select outlet groups to shut down and turn on in a pre-determined order (for UPSs with switched outlet groups).

Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.

Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.

Enables centralized management via StruxureWare Central.

Reduces utlility costs, generates less heat.

Customize UPS capabilities with management cards.

Provides temporary battery power when the utility power is out.

Prolongs battery life by regulating the charge voltage according to battery temperature.

Allows additional run time to be quickly added as needed.

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Availability

Gives higher application availability by correcting low and high voltage conditions without using the battery.

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Protects connected loads from surges, spikes, lightning, and other power disturbances.

Prolongs battery life by regulating the charge voltage according to battery temperature.

Automatically starts up the connected equipment upon the return of utility power.

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Warns when a battery is not available to provide backup power.

Manageability

Provides remote management of the UPS over the network.

Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.

Quickly understand unit and power status with visual indicators.

Provides management of the UPS via a serial port.

Provides management of the UPS via a USB port (not available on all models).

Warns when a battery is not available to provide backup power.

Serviceability

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Provides early-warning fault analysis ensuring proactive component replacement.

Enables a quick recovery from overload events.

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Adaptability

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Safety

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Selv om vi gjør vårt beste for å gi relevant informasjon, så er bildene kun for å gi et generelt inntrykk, og selve varen er ikke nødvendigvis akkurat slik som avbildet. Dersom det er forskjeller mellom produktoverskrift, beskrivelse og bilde, så er det produktoverskriften som gjelder (f.eks. PCer kommer ikke nødvendigvis med skjerm selv om bildet viser det). Hvis noe er uklart, vennligst send epost til kundestøtte før du bestiller. Vi tar forbehold om trykkfeil og endring av priser og spesifikasjoner uten varsel.